Duff-Norton electromechanical actuators are the best packaged solution for your linear actuation needs. With capacities ranging from 100 lbs to 100 tons, no one offers a greater selection of both AC and DC models. This extensive line of models is designed to meet the requirements of the most challenging applications. Benefiting from the latest in advanced design techniques, manufacturing methods, and over three decades of electromechanical product experience, Duff-Norton Electromechanical Actuators last longer and run smoother with minimal maintenance and no headaches. If you have a linear actuation application, Duff-Norton has the packaged solution for you.
Also see PowerMaster range of motor cylinders and synchro cylinders
|
- Input Voltages of: 12 VDC or 24 VDC
- Standard stroke lengths of: 2, 4, 6, 8, 10 and 12 inches
- Adjustable limit switches - optional
- Lifting speeds up to 60 in/min
- Pulse Generator - optional
|
TracMaster™ Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed (In/Min) |
TMD100 |
TMD01-1406 |
2,4,6,8,10,12 |
12 VDC |
|
|
|
M |
585 |
39 |
|
TMD01-1906 |
2,4,6,8,10,12 |
12 VDC |
|
* |
|
M |
450 |
30 |
|
TMD01-2406 |
2,4,6,8,10,12 |
24 VDC |
|
|
|
M |
900 |
60 |
|
TMD01-2906 |
2,4,6,8,10,12 |
24 VDC |
|
* |
|
M |
870 |
58 |
|
- Input Voltages of: 12 VDC or 24 VDC
- Standard stroke lengths of: 2, 4, 6, 8, 10 and 12 inches
- Lifting speeds up to 41 in/min
- Adjustable limit switches - optional
- Pulse generator - optional
|
TracMaster™ Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed (In/Min) |
TMD250 |
TMD02-1406 |
2,4,6,8,10,12 |
12 VDC |
|
|
|
M |
375 |
25 |
|
TMD02-1906 |
2,4,6,8,10,12 |
12 VDC |
|
* |
|
M |
330 |
22 |
|
TMD02-2406 |
2,4,6,8,10,12 |
24 VDC |
|
|
|
M |
630 |
42 |
|
TMD02-2906 |
2,4,6,8,10,12 |
24 VDC |
|
* |
|
M |
495 |
33 |
|
- Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
- Standard stroke lengths of: 3,6,12, and 18 inches
- Lifting speeds up to 86 in/min for AC models and 143 in/min for DC models
- Offered with fully adjustable internal limit switches or travel/load limiting friction disc clutches.
- Potentiometer - optional
|
TracMaster™ Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed (In/Min) |
TMA250-MP |
SPB3405 |
3,6,12,18 |
115 VAC (60 Hz) |
* |
|
|
M |
575 |
40 |
|
SPB4405 |
3,6,12,18 |
220 VAC (50 Hz) |
* |
|
|
M |
435 |
34 |
|
HSPB3405 |
3,6,12,18 |
115 VAC (60 Hz) |
* |
|
|
M |
500 |
86 |
TMD250-MP |
MPD3405 |
3,6,12,18 |
12 VDC |
* |
|
|
M |
1250 |
60 |
|
MPD3404 |
3,6,12,18 |
24 VDC |
* |
|
|
M |
1200 |
66 |
|
HMPD3405 |
3,6,12,18 |
12 VDC |
* |
|
|
M |
1000 |
143 |
TMAL250-MP |
MPB3905 |
3,6,12,18 |
115 VAC (60 Hz) |
|
* |
|
M |
575 |
40 |
|
MPB4905 |
3,6,12,18 |
220 VAC (50 Hz) |
|
* |
|
M |
435 |
34 |
|
HMPB3905 |
3,6,12,18 |
115 VAC (60 Hz) |
|
* |
|
M |
500 |
86 |
|
PMPB3905 |
3,6,12,18 |
115 VAC (60 Hz) |
|
* |
* |
M |
575 |
40 |
|
PMPB4905 |
3,6,12,18 |
220 VAC (50 Hz) |
|
* |
* |
M |
435 |
34 |
|
PHMPB3905 |
3,6,12,18 |
115 VAC (60 Hz) |
|
* |
* |
M |
500 |
86 |
TMDL250-MP |
MPD3905 |
3,6,12,18 |
12 VDC |
|
* |
|
M |
1250 |
60 |
|
MPD3904 |
3,6,12,18 |
24 VDC |
|
* |
|
M |
1200 |
66 |
|
HMPD3905 |
3,6,12,18 |
12 VDC |
|
* |
|
M |
1000 |
143 |
|
- Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
- Standard stroke lengths of: 3,6,12, and 18 inches
- Lifting speeds up to 79"/min for AC models and 50"/min for DC models
- Offered with fully adjustable internal limit switches or travel/load limiting friction disc clutches.
- Potentiometer - optional
|
TracMaster™ Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed (In/Min) |
TMA500-MP |
|
3,6,12,18 |
|
* |
|
|
M |
500 |
35 |
|
SPB7405 |
3,6,12,18 |
|
* |
|
|
M |
435 |
32 |
|
|
3,6,12,18 |
|
* |
|
|
M |
500 |
79 |
TMD500-MP |
|
|
12 VDC |
* |
|
|
M |
450 |
44 |
|
|
3,6,12,18 |
24 VDC |
* |
|
|
M |
|
50 |
TMAL500-MP |
MPB6905 |
3,6,12,18 |
|
|
* |
|
M |
500 |
35 |
|
MPB7905 |
3,6,12,18 |
|
|
* |
|
M |
435 |
32 |
|
|
3,6,12,18 |
|
|
* |
|
M |
500 |
79 |
|
|
3,6,12,18 |
|
|
* |
* |
M |
500 |
35 |
|
|
3,6,12,18 |
|
|
* |
* |
M |
435 |
32 |
|
|
3,6,12,18 |
|
|
* |
* |
M |
500 |
79 |
TMDL500-MP |
|
3,6,12,18 |
12 VDC |
|
* |
|
M |
450 |
44 |
|
|
3,6,12,18 |
24 VDC |
|
* |
|
M |
500 |
50 |
|
- Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
- Standard stroke lengths of: 4,8,12 and 18 inches
- Lifting speeds up to 32" /min for AC models and 24" /min for DC models
- Fully adjustable internal limit switches are standard
- Potentiometer - optional
|
TracMaster™ Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle† (In/Hr) |
Lifting Speed (In/Min) |
TMAL-750 |
LSPA3275 |
4,8,12,18 |
115 VAC (60 Hz) |
|
* |
|
M |
290 |
15 |
|
LSPA4275 |
4,8,12,18 |
220 VAC (50 Hz) |
|
* |
|
M |
145 |
12 |
|
HLSPA3275 |
4,8,12,18 |
115 VAC (60 Hz) |
|
* |
|
M |
480 |
32 |
|
HLSPA4275 |
4,8,12,18 |
220 VAC (50 Hz) |
|
* |
|
M |
450 |
30 |
|
PLSPA3275 |
4,8,12,18 |
115 VAC (60 Hz) |
|
* |
* |
M |
290 |
15 |
|
PLSPA4275 |
4,8,12,18 |
220 VAC (50 Hz) |
|
* |
* |
M |
145 |
12 |
|
PHLSPA3275 |
4,8,12,18 |
115 VAC (60 Hz) |
|
* |
* |
M |
480 |
32 |
|
PHLSPA4275 |
4,8,12,18 |
220 VAC (50 Hz) |
|
* |
* |
M |
450 |
30 |
TMDL750 |
LSPD2775 |
4,8,12,18 |
12 VDC |
|
* |
|
M |
360 |
22 |
|
LSPD2774 |
4,8,12,18 |
24 VDC |
|
* |
|
M |
459 |
24 |
|
PLSPD2775 |
4,8,12,18 |
12 VDC |
|
* |
* |
M |
360 |
22 |
|
PLSPD2774 |
4,8,12,18 |
24 VDC |
|
* |
* |
M |
459 |
24 |
|
- Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
- Standard stroke lengths of: 3,6,12, 18 and 24 inches
- Lifting speeds up to 53" /min for AC models and 39" /min for DC models
- Fully adjustable internal limit switches are standard
- Potentiometer - optional
|
TracMaster™
Series |
Model |
Stroke Length
(inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle† (In/Hr) |
Lifting Speed (In/Min) |
TMAL1000-HD |
SPA 3410 |
3,6,12,18,24 |
115 VAC (60 Hz) |
|
* |
|
B |
900 |
53 |
|
SPA 4410 |
3,6,12,18,24 |
220 VAC (50 Hz) |
|
* |
|
B |
1000 |
50 |
|
PSPA 3410 |
3,6,12,18,24 |
115 VAC (60 Hz) |
|
* |
* |
B |
900 |
53 |
|
PSPA 4410 |
3,6,12,18,24 |
220 VAC (50 Hz) |
|
* |
* |
B |
1000 |
50 |
TMDL1000-HD |
LSPD2910 |
3,6,12,18,24 |
12 VDC |
|
* |
|
B |
885 |
39 |
|
LSPD2909 |
3,6,12,18,24 |
24 VDC |
|
* |
|
B |
1085 |
38 |
|
PSPD2910 |
3,6,12,18,24 |
12 VDC |
|
* |
* |
B |
885 |
39 |
|
PSPD2909 |
3,6,12,18,24 |
24 VDC |
|
* |
* |
B |
1085 |
38 |
|
- Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, and 12 VDC
- Standard stroke lengths of: 3,6,12, 18 and 24 inches
- Lifting speeds up to 50" /min for AC models and 26" (685 mm)/min for DC models
- Offered with fully adjustable internal limit switches or travel/load limiting friction disc clutches.
- Potentiometer - optional
|
TracMaster™ Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle† (In/Hr) |
Lifting Speed (In/Min) |
TMD1500-SP |
SPD6415 |
3,6,12,18,24 |
12 VDC |
* |
|
|
M |
400 |
26 |
TMAL1500-SP |
SPA6415 |
3,6,12,18,24 |
115 VAC (60 Hz) |
|
* |
|
M |
500 |
50 |
|
SPA7415 |
3,6,12,18,24 |
220 VAC (50 Hz) |
|
* |
|
M |
600 |
41 |
|
PSPA6415 |
3,6,12,18,24 |
115 VAC (60 Hz) |
|
* |
* |
M |
500 |
50 |
|
PSPA7415 |
3,6,12,18,24 |
220 VAC (50 Hz) |
|
* |
* |
M |
600 |
41 |
TMDL1500-SP |
LSPD6415 |
3,6,12,18,24 |
12 VDC |
|
* |
|
M |
400 |
26 |
|
- Input Voltages of: 115 VAC, 60 Hz or 220 VAC, 50 Hz
- Standard stroke lengths of: 3,6,12, 18 and 24 inches
- Lifting speeds up to 52 in/min
- Fully adjustable internal limit switches are standard clutches.
- Potentiometer - optional
|
TracMaster™ Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle† (In/Hr) |
Lifting Speed (In/Min) |
TMD2000-SP |
SPD6420 |
3,6,12,18,24 |
12 VDC |
* |
|
|
B |
600 |
27 |
TMAL2000-SP |
SPA6420 |
3,6,12,18,24 |
115 VAC (60 Hz) |
|
* |
|
B |
600 |
52 |
|
SPA7420 |
3,6,12,18,24 |
220 VAC (50 Hz) |
|
* |
|
B |
625 |
41 |
|
PSPA6420 |
3,6,12,18,24 |
115 VAC (60 Hz)
|
|
* |
* |
B |
600 |
52 |
|
PSPA7420 |
3,6,12,18,24 |
220 VAC (50 Hz) |
|
* |
* |
B |
625 |
41 |
|
- Integral housing flange engineered for NEMA 56 frame motor, C-face mounting. (NEMA 42 and 48 and IEC 71 frame motor C-Face mounting option available.)
- Four basic models: 2 rotating screw with traveling lift nut; two translating tube with protective aluminum outer sleeve.
- Rated load to 2,000 pounds, depending on actuator model, gear ratio and motor horsepower.
- Choice of 5:1 or 20:1 worm gear ratios.
- Lift speeds to 345 inches per minute.
- Standard travel up to 24 inches. (Consult PT Link Systems engineering for longer travel options.)
- Housing base bolt pattern will accept standard hydraulic and pneumatic fitting for end attachments.
- Can be tandem-coupled for synchronous operation.
- Optional motors, limit switches and position indication transducer available.
- Clevis attachment accessories available for mounting: eye bracket, clevis bracket and pivot pin.
|
|
- Package Controls Available in two sizes: 6 x 6 x 4 inches (152 x 152 x 102 mm) and 4 x 4 x 3 inches (102 x 102 x 77 mm).
- NEMA 12 and 13 CSA Type 12 enclosure
- Illuminated rocker type momentary contact with power-on indicator light extend/retract switch
- ANSI 61 Gray polyester powder coating finish
- 16 Gauge steel housing
- Oil resistant gasket
- External feet mounting
- Power Supplies
- Pendant Controls
- For use with TMD01, PTMD01, TMD02, and PTMD02 12 VDC and 24 VDC actuators
- NEMA 1 polycarbonate enclosure
- Can be used as a handheld pendant station or surface mounted
|
Also see PowerMaster range of motor cylinders and synchro cylinders
|
|